中文  | English
繁体中文

Finance and data center

Your Current Location : Home Solution Finance and data center

Solution

Search:
Bank power solution

Name:Bank power solution

Finance, database Turbo power solution guarantee the stability for finance and data center.Non-stop power supply is the core and basis for security of financial facilities and database, with the development in economy and society, the requirement of economical and more steady would be higher required for database, especially , with the appearance of large scare database and Cloud Computing ,it strictly regulate the standby power 's stability.

Details
Turbo generator coupled with PMG alternator, could add the linear load and other load effectively, can afford the low harmonic shock, Turbo power solution have been applied widely in banking, financial, database. Beside of auto-start, auto-switch, auto-operation, AAT and auto-stop function, Turbo generator configurated with remote monitoring, control , PMG functions and so on.
Requirements and Challenges
Bank system have high demanding in Anti-interference or other environment, which strictly regulate the performance  stability , auto-switch and ATS function, instantaneous start time, low noise, security and so on.
 
1、Working condition
24 hours consecutive stable power output at rated power (10% overload for 1 hour permissible each 12 hours),
Altitude height: 1000 meters,
Humidity: 60%
Temperature lower limit -40°C, upper limit 55°C
Other environment adapt gensets available in some Special area (customization available)
2、Low noise and clean emission
Super low noise power supply ensure an undisturbed working environment, noise level below 70dB(A) at 1 meter distance.
 
3、Necessarily protective equipments
The machine can automatically inspect the start battery voltage and give an alarm. The machine will automatically stop and give relevant signals in the following cases: low oil pressure, high water temperature, low water level, over load, start failure, over speed, short circuit, phase lack, over voltage, voltage loss, low frequency, low voltage for start battery, low oil level and relay connection in the alarm system.

When the main fails, the control panel will auto start after the confirmation(0-60s adjustable). The power gensets can start itself consecutively for three times( 5s start, 2-3s running before loading). When the frequency and voltage reach the rated value, the control panel will give ATMa signal to automatically switch the main loading to gensets load; when the main power gets back, the control panel will give the ATS a signal to automatically switch the gensets loading to main load after the confirmation(0-60 mins delay adjustable), the gensets will automatically stopafter cooling (0-60 minsdelayadjustable)and thenstand by. The gensets could start successfully at the rate 99%.
4、Stable performance & high reliability
Average failure interval: not less than 3000 hours
Technical parameters:steady-statevoltage regulation≦±0.5%,transient voltage regulation≦±15%.steady time1.0s.on no load:line voltage sin waveform distortion <3%,volatility <0.5%; steady-state frequency regulation≦±0.5%,transient frequency regulation≦±5%,steady time <3s,volatility≦0.5%)Advanced diesel engine control system and excellent ECU alarming function. Self-faults diagnostic system can detect engine fault codes. Low oil consumption.
 
Power Solution
Superb power gensets, with low noise design, configured with auto control system, connected ATS to ensure the standby power could supply immediately once the main fails. The power supply is stable, low noise and optimized exhausting, which is compliant withthe Germany TA-Luft Standard,the U.S. California Air Resources Board( CARB) standard,U.S.Environmental Protection Agency(EPA) standard and European off-highway emission standard. The automatic control and ATS could satisfy the broadcasting and television’s special requirements. The machine can be connected with computer(friendly interface, operation software in both Chinese and English)with RS232 or RS485/422 connector torealizeremote control, remote signaling and telemetering automatically at unattended operation.
 
Advantages.
Adopt standard design, the spare parts are compatible, convenient for maintenance.
Coupled with PMG alternator, high stability, Sudden load ability, Low affection on low harmonic shock.
Whole set product andturn-keysolution help customer use and maintain the machine easily without much technical knowledge.
The control system could realize auto switch, auto start, auto stop and alarming.
When gensets supply electric to phase controlled rectifier, switching power, UPS power or other load, will not happen the low-frequency oscillating if the start-load lower than 50% regulated value.
Save cost and well environment protection, low consumption, superb emission index, low noise (under 70db at 1.0m distance)
Compact size, some special options are provided to meet demand in the cold, tropical areas.
For bulk order, custom design and development is provided.